Created a 4,000 SqFt Addition to the Existing Building, including Grade Beams and Piers. Remodified the Entire 22,000 SqFt Parking Lot with 1,275 LF of Monolithic Curb.









Scope of work:
Concrete
o (33) 18” diameter concrete piers with a 36” Bell. (2) 24” diameter concrete piers with a 48” Bell. (4) 24” diameter concrete piers with a 54” Bell. All piers are bid at 20’ deep. Piers bid dry. Reinforcement per plans.
o 85 LF of 6” thick Retaining Wall for the Building Planter. Reinforcement per plans.
o 42 LF of Dirt Formed concrete grade beam for the Dumpster Pad. Reinforcement per plans.
o 720 LF of Dirt Formed concrete grade beam for the Exterior Building Slab – Void Forms Included. Reinforcement per plans.
o 134 SqFt of 8” of concrete SOG for the Dumpster Pad. Reinforcement per plans.
o 4,241 SqFt of 5” of concrete SOG for the Exterior Building Slab. Reinforcement per plans.
o Install 1,659 SqFt of 8” of Drive Concrete Paving. Reinforcement per plans (#4 Rebar).
o Install 8,417 SqFt of 6” of Heavy-Duty Concrete Paving. Reinforcement per plans (#4 Rebar).
o Install 12,653 SqFt of 5” of Light-Duty Concrete Paving. Reinforcement per plans (#4 Rebar).
o Install 1,275 LF of Concrete Monolithic Curb. Reinforcement per plans (#4 Rebar).
o Install 380 SqFt of 4” of Concrete City Sidewalk. Reinforcement per plans (#3 Rebar).
o Install 1,450 SqFt of 4” of Concrete Private Sidewalk. Reinforcement per plans (#3 Rebar).
o (3) Light Pole Bases, installed per plans.
o (3) Bollards – installed only, steel pipe to be provided by GC.
o (2) Dumpster Enclosure Pipe – Installed only, steel to be provided and installed by other.
Services: Concrete Building Addition and Parking Lot Modification.